There are many weak motor cabinets, servers, wiring frames, routers and other equipment in the server room, and all these devices are tightly linked to each other, and one is indispensable. So, what problems need to pay attention to the installation position of the weak motor cabinet in the server room? Weak power room cabinet how to line it up?
Weak power room is also called weak power room. The so-called weak power is for electricity, lighting power relative. Usually, the electricity, lighting with electricity is called strong; and the electrical energy to propagate signals, information exchange is called weak. The object of strong electricity is energy (electricity), which is characterized by high voltage, high current, high power consumption, low frequency, the main consideration is to reduce losses and improve efficiency;
Weak power engineering includes TV engineering, communication engineering, fire engineering, security engineering, video engineering, etc. and integrated wiring engineering which serves the above engineering. Weak power is for strong power. Strong power = (380/220), high voltage regardless.
Weak electricity well is used to lay weak electricity line (cable) a (should say) channel. Weak power well in the designated floor will be set up to check the mouth, to facilitate the professional staff to check the weak power lines (cable) with.
Weak power lines (cable) laid in the weak well that can protect the weak lines (cable) to reduce man-made damage, but also to facilitate the professional construction staff to check the maintenance of regular, and lines (cable) from the weak well, will not affect the overall impact of the building, more beautiful. Weak electricity is not only refers to communications, in fact, cable TV lines (cables), fire alarm lines (cables) and so on are weak electricity.
1, the wiring subsystem cable length control within 90 meters.
2, as far as possible to set up **, IT special management of the weak power room.
3, it is advisable to use floor-type cabinets, and leave equipment installation and maintenance space on all sides of the cabinet.
4, the weak power room / wiring cabinet should not have abnormal odor around, so as not to damage the equipment or maintenance personnel difficult to work.
5, When the weak power room is shared with other departments, try to isolate the space around the weak power cabinet, so that this space becomes IT exclusive use.
6, For the weak power room or common area that can not be locked, should always check, once encountered cabinet damage, water leakage or cable / equipment is "buried" in other departments of the information or goods, need to discuss with the joint department, as soon as possible to clean up neatly, so as to avoid unnecessary trouble in future maintenance.