As the cabinet type wiring frame has become the main body of the wiring frame in the server room, how can the cabinet in the weak power room be organized to look good? The following to introduce you.
Network cables should be arranged according to the topology of the network and existing equipment; cabinet power lines and network cables should be arranged separately in principle; equipment should be properly placed to avoid squeezing each other, avoid too high or too low, and avoid being too close to each other; if there are too many devices in the cabinet, the equipment should be numbered; each line should be marked in the appropriate location with different connection methods (such as general network connection lines, cross lines, special lines, etc.); network The arrangement of lines is based on the room number rather than on the person. Overall, the lineup is regular, clearly marked, clearly laid out, and easy to maintain.
1. Preliminary preparation
First, without affecting the normal work of the user, the user must be notified to clean up the cabinet, and then according to the topology of the network, the existing equipment, the number of users, user grouping and other factors. Outline the wiring diagram and equipment layout in the cabinet; next, prepare the required materials: label paper, network jumper, various types of plastic tape.
2. Organize the cabinet
Install the cabinet.
What we need to do is: use the random frame screws and nuts to tighten the brackets, remove the cabinet, install the movable wheels, adjust and add baffles to the retainers according to the position of the equipment.
Organize the wiring.
Tie the power cables of all the devices together, insert the plugs through the through holes from the back and look for the respective devices through the separate wire racks, group the network wiring in groups usually smaller or equal to the number of wire frames at the back of the cabinet,.
Secure equipment.
Adjust the baffle in the cabinet to the proper position so that the administrator can see the operation of all devices without opening the cabinet door. And add baffles appropriately according to the number and size of the devices, taking care to leave a certain gap between the baffles. Place all switchgear and cabling devices used in the cabinet according to the pre-drawn diagram.
Network cable labeling.
Once all network lines are connected, each network cable must be labeled. Wrap prepared instant stickers around the network cable and mark it with a pen (usually indicating the room number or purpose), requiring easy-to-understand markings. Cross-network cables can be distinguished from normal network cables by using different color instant stickers. If there are too many devices, sort and number the devices and label them.
The above is to share with you about the content of the server room cabinet, hope that through the above content, can make you have a better understanding of the weak power room cabinet and understanding.