Controlling energy costs starts with understanding hot aisle containment options that focus on reducing energy costs without reducing protection. When you consider that the average air conditioning cost for an average-sized server room is about $23,000 per year and produces 243 tons of greenhouse gases, you can see why energy efficiency should be a priority.
What can you do to reduce your data center containment costs and reduce your carbon footprint? That's the million-dollar question. You can start by evaluating your current system to learn more about hot aisle containment solutions that address energy concerns.
What you need to know about solutions and energy efficiency
Unfortunately, there is no magic wand to help reduce energy costs in a hot aisle containment or cold aisle containment environment, but there are steps you can take to make your system more efficient.
Industry experts may disagree on which system is best, but they all agree that no system is desirable, and there is an additional caveat. Improperly implementing a solution is just as bad as having no solution at all.
When setting up a hot aisle containment system, there are specific "do's" and "don'ts" that you should follow to ensure you get the highest energy efficiency. Following these simple "do's" and "don'ts" will ensure that you are doing your part to reduce the amount of energy required to secure your IT equipment.
To get the most out of your hot aisle containment solution, you have to do your part! Here are some "do's" that can help you get started on the path to curbing energy consumption
Use your existing architecture to your advantage
Accurately measure your IT load
Audit system requirements frequently
Create a baseline so you can measure success
Adjust set points in time after observations
Enlist the help of a trusted expert
Taking several steps can help curb your data center in the right direction for energy efficiency. Other practices include using the correct server rack size. The design of electronic enclosures can play an important role in the efficiency of containment solutions.
Now the caveat
The caveat for hot aisle containment solutions is.
Don't seal your aisles
Don't force a containment system on a structure that is not suitable for that type of system
Don't assume a containment system is ideal for your space based on systems in other spaces, even if they are similar. The best approach is to evaluate your needs.
The bottom line is that when it comes to hot aisle containment options and how they can reduce your energy consumption, you need to do your homework. One of the best ways to do this is to contact an expert in the field who can help you find the best solution.